Smokeless Medical / Hospital / Clinical Pharmaceutical Waste Incinerator

Hazardous waste incinerator by Mechanical Lifting Device (optional), Main Combustion Chamber, Secondary Combustion Chamber, Lye Scrubber Tower, Cooling Soil Pool, Cyclone Dust Collector Tower, Bag Dust Collector Tower, Duced Draft Fan, Chimney composition.

The core of a high-temperature pyrolysis gasifier is dioxins suppression. In the secondary combustion chamber using peroxygenic combustion, the temperature control at 850-1200°C gas retention time ≥2S, can make polychlorinated biphenyls, carbon residues and other complete combustion of contact so that the dioxin residue is very little.

The mechanical lifting device can be selected to completely close the input of the whole system and reduce the infection and injury of medical waste to personnel.

  • Product Description
  • Technical Parameters
  • Video

Smokeless Medical Hospital Clinical Pharmaceutical Waste Incinerator Description:
Medical waste incinerator is a direct incineration devices instead of steam sterilization. The waste material burns in the furnace and enters the secondary combustion chamber as waste gas. Completely burned in the forced combustion of the burner, and then into the flue gas purification device. After the dust is removed, it is discharged into the atmosphere through a chimney. Medical waste incinerator is a kind of harmless treatment equipment. It is often used in medical waste treatment, animal waste cremation, domestic waste treatment, industrial waste incineration treatment and special waste treatment. Cheap, compared with steam treatment, combustion emissions have a certain amount of air pollution.

Smokeless Medical / Hospital / Clinical Pharmaceutical Waste Incinerator application

Application Areas:
Hospitals and clinics: medical waste, infectious waste, dressings, biological waste, medicine.

 

Smokeless Medical Hospital Clinical Pharmaceutical Waste Incinerator features:
The medical waste incinerator has the advantages of compact volume, high combustion effect, reasonable combustion process and high degree of no harm. It is an ideal choice for waste disposal in hospitals, hotels and various areas.
The waste incinerator consists of a furnace body, a blower, a chimney and an electrical control system. There are four chambers: the primary combustion chamber, the secondary combustion chamber, the mixture combustion chamber and the smoke purification chamber.

1. Gasification and pyrolysis incineration is used to burn a variety of wastes.

2. Easy to operate, low cost of operation and maintenance.

3. Gasification incineration, mixed incineration and burnout treatment can ensure low emission standards of dust and dioxins.

4. Fully closed operation is suitable for the treatment of infectious waste to avoid secondary pollution.

5. Compact structure, less space.

6. The highest temperature can reach 1100 ~ 1300 ℃, which can realize sterilization.

 

Medical Waste Incinerators Working Principle:
Hazardous waste incinerator by Mechanical Lifting Device (optional), Main Combustion Chamber, Secondary Combustion Chamber, Lye Scrubber Tower, Cooling Soil Pool, Cyclone Dust Collector Tower, Bag Dust Collector Tower, Duced Draft Fan, Chimney composition.

The core of a high-temperature pyrolysis gasifier is dioxins suppression. In the secondary combustion chamber using peroxygenic combustion, the temperature control at 850-1200°C gas retention time ≥2S, can make polychlorinated biphenyls, carbon residues and other complete combustion of contact so that the dioxin residue is very little.

The mechanical lifting device can be selected to completely close the input of the whole system and reduce the infection and injury of medical waste to personnel.

medical waste incineration and disposal

Advantages of medical waste incinerator:
The specific advantages of Medical waste incinerators for medical waste treatment are mainly reflected in five aspects:

(1) After the medical waste incinerator, the pathogens are completely eliminated, and the toxic and harmful gases and soot generated in the combustion process are treated to meet the discharge requirements, with a high degree of harmlessly:

(2) After incineration, the combustible components in the garbage are decomposed at high temperature, generally can reduce capacity by 80%, 90%, the reduction effect is good, and can save a lot of landfill area, after sorting the garbage incineration effect is better:

(3) Waste is used as energy. The high-temperature flue gas generated by waste incineration is absorbed and converted into steam by a waste heat boiler for heating and power generation. Ferromagnetic metals and other resources can be recovered, which can fully realize the recycling of waste treatment:

(4) Waste incineration plant covers a small area, exhaust gas purification treatment after less pollution, can be close to the city to build a factory, both to save land and shorten the transport distance of waste, for economically developed cities, can adapt to local conditions, the development of incineration, reduction of comprehensive treatment.
Incineration treatment can be an all-weather operation, not easy to be affected by the weather.

 

Combustion process and brief description:
The waste is manually put into the primary combustion chamber of the furnace body, and the automatic temperature control starts the primary combustion. According to the principle of three T (temperature, time and eddy current), oxidation, pyrolysis and combustion are fully carried out in the combustion chamber of the furnace body. The flue gas produced by incineration enters the secondary combustion chamber, and the unburned harmful substances in the flue gas are further destroyed in the secondary combustion chamber. In order to completely decompose the unburned material and meet the discharge requirements, the second combustion chamber is equipped with a burner to assist combustion and a unique secondary air supply device to ensure that the flue gas is in full contact with oxygen at high temperature, and at the same time ensure the retention time of flue gas in the second combustion chamber and adjust the air supply according to the oxygen content of flue gas at the exit of the second combustion chamber. Two combustions indoor temperature control and through the dust collector to remove dust particles larger, the burning efficiency and removal rate of more than 99%, to no peculiar smell, no stink, smoke-free effect, meet the national discharge standard, and then into the chimney emissions into the atmosphere, after burning ash produced by artificial remove, screening, transfer and buried.

medical waste incineration and disposal

Medical Waste Incinerator Working rules:
The hazardous waste incinerator adopts the most advanced combustion mode of primary pyrolysis gasification + ambient air mixing + secondary incineration + burnout treatment.

1. The design of the primary combustion chamber adopts gasification and incineration technology to raise the temperature In the incinerator from 200 ° C to 400 ° C so that the garbage will not face problems the as dissolving, slagging and sintering in the incineration process.

2. The secondary incineration burner and the circumferential air supply are installed in the secondary mixing incineration chamber. At high temperatures, the combustible gas in the flue gas can be fully combusted, and the gas generated by the gasifier can be fully mixed with air for combustion with high efficiency to prevent carbon substances in the flames from overflowing and burning late. Turbulent combustion will completely remove black smoke and odors. Inhibit the production of toxic and harmful substances such as dioxins at the source.

3. When the flue gas enters the high-temperature combustion chamber, tangential entry and tangential entry of combustion-supporting air are adopted so that the flue gas can be fully combusted again in the combustion chamber, and the flue gas is dedusted by rotating airflow so that the residence time of the incineration flue gas in the furnace is longer than 2 seconds, and the combustible gas in the flue gas and fly ash are completely incinerated.

4. The upper part of the incinerator is equipped with dry tail gas purification equipment to absorb hydrogen chloride, sulfur oxides and other components generated in the incineration so that odor and other components in the flue gas are decomposed at high temperatures. The flue gas purification system is equipped with a calcium hydride filter to carry out neutralization reaction with acid gas to achieve the purpose of adsorbing acid gas and purifying tail gas.

5. The harmful components in the flue gas are reduced to below the national standards.

Leave a Reply

Your email address will not be published. Required fields are marked *

Model Dimensions(mm) Power(kw) Chimney(mm) Weight(kg) Capacity
WRMI-20 900*600*700 0.44 Φ140*6m 1500 10-20kg/batch
WRMI-30 1450*900*1020 0.63 Φ159*6m 2000 20-30kg/batch
WRMI-50 1800*1160*1200 0.81 Φ219*6m 3000 30-50kg/batch
WRMI-150 2000*1200*1360 1.01 Φ219*6m 4500 100-150kg/batch
WRMI-300 2200*1570*1510 1.8 Φ530*6m 8500 200-300kg/batch
WRMI-500 3000*1750*1710 3.34 Φ620*6m 12000 300-500kg/batch